Perle 27030168 - PP-RJ-SC DIN Rail Patch Panel: 1 x RJ45 socket, 1 x screw terminal block, 10/100/1000 Mbps, IP20 by PERLE
|
|
|
|
|
|
|
Ethernet patch panels make the connection between field cabling and control cabinet cabling quick and easy. A PP-RJ DIN Rail Patch Panel is ideal for installation inside control panels and distribution cabinets where one-to-one simplified connections need to be made. A standard Ethernet patch cable is used between the patch panel and the control cabinet equipment, such as switches, PLCs and routers. Through ICD, Push-in, Screw or RJ45 connectors, field wiring is easily connected to the patch panel and protected inside a covered wiring space. The cable shielding is connected quickly and easily, without tools, while simultaneously ensuring strain relief. This simplifies installation of the field cable and saves a great deal of time during installation. PP-RJ DIN Rail Patch Panels provide the perfect mix of density and flexibility to decrease network risk and improve cable organization in scalable deployments with constricted spaces.
Ideal applications for PP-RJ DIN Rail Patch Panels
- Inside equipment cabinets with DIN rails
- Alongside Industrial Ethernet switches and RJ45 (Ethernet or Serial) PLCs
- Alongside other DIN Rail RJ45 (Ethernet or Serial) control devices
- Where growth from one to many ports is needed to support high-density installations. Multiple one port DIN Rail Patch Panels can installed side-by-side to grow, as required by the customer application.
Benefits of PP-RJ DIN Rail Patch Panels
| Multiple connection technologies |
For greater flexibility and time savings during installation you can choose between IDC, Push-in, Screw, and RJ45 connections.
- RJ45 – standard RJ45 Ethernet type connector
- IDC Terminal Block – due to the tool used, it offers increased productivity and security
- Push-in Terminal Block – wires can be pushed-in, no tool required
- Screw Terminal Block – used for tight connections
|
| Covered cable wiring space |
A hinged cover protects the wiring space on the field cable side with connection terminal blocks and shield contacting. This ensures a uniform installation pattern. In addition to this visual extra, the sensitive connection wires are protected from external influences. |
| Quick tool-free shield connection with no loose parts |
The cable shielding can be connected to the device quickly and easily without tools – with strain relief assured at the same time. Simply lay the cable in the shaft provided, close the shroud and, you're done.
 |
| DIN Rail Enclosure |
Easily mount on a DIN rail or inside distribution boxes using native DIN Rail enclosure with grounding clip. No need for add-on brackets. |
| Low profile design |
The low-profile design minimizes cable bend radius in shallow enclosures where space is a premium as well as providing secure cable strain relief. |
| Serial interface |
| Interface 1 |
Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
| Connection method |
Screw terminal block |
| Transmission length |
100 m (including patch cables) |
| Conductor cross section solid min. |
0.14 mm² |
| Conductor cross section solid max. |
1.5 mm² |
| Conductor cross section flexible min. |
0.14 mm² |
| Conductor cross section flexible max. |
1.5 mm² |
| Conductor cross section AWG min. |
28 |
| Conductor cross section AWG max. |
16 |
| Wire diameter incl. insulation |
1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request) |
| Pin assignment |
1:1 |
| Serial transmission speed |
10/100/1000 Mbps |
| Output nominal voltage |
< 60 V (ATEX approval) |
|
< 57 V DC (With UL approval) |
| Maximum output current |
725 mA (Per channel) |
| Maximum output power |
60 W |
| Interface 2 |
Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
| Connection method |
RJ45 CAT5e |
| Stripping length |
5 mm |
| Torque |
0.22 Nm ... 0.25 Nm |
| Ambient conditions |
| Ambient temperature (operation) |
-40°C ... 75°C |
| Ambient temperature (storage/transport) |
-40°C ... 85°C |
| Permissible humidity (operation) |
10 % ... 95 % (non-condensing) |
| Altitude |
5000 m (For restrictions see manufacturer's declaration) / 2000 m (ATEX approval) |
| Degree of protection |
IP20 (Manufacturer's declaration) |
| General |
| Net weight |
124.2 g |
| Housing material |
Plastic |
| Color |
Gray |
| MTTF |
105699 Years |
| Degree of pollution |
2 |
| Overvoltage category |
II |
| Conformance |
CE-compliant |
| ATEX |
II 3 G Ex nA IIC Gc U |
| UL, USA |
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
| UL, Canada |
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
| Standards and Regulations |
| Type of test |
Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
| Test result |
10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g |
| Type of test |
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| Test result |
30g for 11 ms, three shocks in each spatial direction |
| Type of test |
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 |
| Test result |
10g for 16 ms, 1000 shocks in each spatial direction |
| Rated insulation voltage |
85 V DC |
| Conformance |
CE-compliant |
| ATEX |
II 3 G Ex nA IIC Gc U |
| UL, USA |
UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
| UL, Canada |
CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
| Noxious gas test |
ISA-S71.04-1985 G3 Harsh Group A |
| Dimensions |
| Caption |
Compact housing |
| Width |
23.8 mm |
| Height |
101.3 mm |
| Depth |
50 mm |
| Approvals |
|
| Environmental Product Compliance |
| China RoHS |
Environmentally Friendly Use Period = 50 |
|
|
|
|